Personal tools

2013

Bart Maesen, Stef Zeemering, Carlos Afonso, Jens Eckstein, Rebecca AB Burton, Arne van Hunnik, Daniel J Stuckey, Damian Tyler, Jos Maessen, Vicente Grau, Sander Verheule, Peter Kohl, Ulrich Schotten - Rearrangement of Atrial Bundle Architecture and Consequent Changes in Anisotropy of Conduction Constitute the 3-Dimensional Substrate for Atrial Fibrillation - Circulation: Arrhythmia and Electrophysiology 2013/10/1   6(5): 967-975 http://dx.doi.org/10.1161/CIRCEP.113.000050

Alfonso Bueno-Orovio, David Kay, Vicente Grau, Blanca Rodriguez, Kevin Burrage Fractional diffusion models of cardiac electrical propagation: role of structural heterogeneity in dispersion of repolarization 2013 Nature Communications

Ayush Goyal, Jack Lee, Pablo Lamata, Jeroen van den Wijngaard, Pepijn van Horssen, Jos Spaan, Maria Siebes, Vicente Grau, Nic P Smith - Model-based vasculature extraction from optical fluorescence cryomicrotome images - 2013/1 - Medical Imaging, IEEE Transactions on 32 (1): 56-72


A Mehndiratta, BJ MacIntosh, DE Crane, SJ Payne, MA Chappell
A control point interpolation method for the non-parametric quantification of cerebral haemodynamics from dynamic susceptibility contrast MRI.
NeuroImage, 64, 1 Jan 2013: 560–570 http://dx.doi.org/10.1016/j.neuroimage.2012.08.083
 
MA Chappell, MW Woolrich, S Kazan, P Jezzard, SJ Payne,  BJ MacIntosh.
Modeling dispersion in arterial spin labeling: Validation using dynamic angiographic measurements.
Magnetic Resonance in Medicine 69(2) Feb 2013: 563-570 http://dx.doi.org/10.1002/mrm.24260
 
SL Collins, G Stevenson, J A Noble, L Impey.
Rapid calculation of standardised placental volume at 11-13 weeks and the prediction of the term, small for gestational age baby.
Ultrasound in Medicine and Biology, ; 39(2): 2013 Feb: 253-60 http://dx.doi.org/10.1016/j.ultrasmedbio.2012.09.003
 
 M Tee, JA Noble, DA Bluemke.
Imaging techniques for cardiac strain and deformation: comparison of echocardiography, cardiac magnetic resonance and cardiac computed tomography.
Expert Review of Cardiovascular Therapy 11(2), Feb 2013: 221-231 http://dx.doi.org/10.1586/erc.12.182
  
SL Collins, GN Stevenson, JA Noble, L Impey.
Elsevier Trophoblast Research Award Lecture: Searching for an early pregnancy 3-D morphometric ultrasound.
Placenta. 34 Suppl: S85-89. March 2013 http://dx.doi.org/10.1016/j.placenta.2012.11.033
 
IJA Simpson, Mark W. Woolrich, JLR Andersson, AR Groves, JA Schnabel and the Alzheimer’s Disease Neuroimaging Initiative.
Ensemble learning incorporating uncertain registration.

IEEE Transactions on Medical Imaging, 32(4):April 2013: 748 -756.  http://dx.doi.org/10.1109/TMI.2012.2236651

Piotr Orlowski, David O'Neill, Vicente Grau, Yiannis Ventikos, Stephen Payne - Modelling of the physiological response of the brain to ischaemic stroke
2013/4/6 - Interface focus 3 (2) 20120079

Gemma Piella, Mathieu De Craene, Constantine Butakoff, Vicente Grau, Cheng Yao, Shahrum Nedjati-Gilani, Graeme P Penney, Alejandro F Frangi  - Multiview diffeomorphic registration: Application to motion and strain estimation from 3D echocardiography Medical image analysis Volume 17(3) 2013/4/30 348-364 - http://dx.doi.org/

DE Crane, MJ Donahue, MA Chappell, E Sideso, A Handa, J Kennedy, P Jezzard, BJ MacIntosh.  Evaluating quantitative approaches to dynamic susceptibility contrast MRI among carotid endarterectomy patients.   Journal of magnetic resonance imaging, 37(4), April 2013: 936–943. http://dx.doi.org/10.1002/jmri.23882 

AIL Namburete, JA Noble.
Fetal Cranial Segmentation in 2D Ultrasound Images using Shape Properties of Pixel Clusters.
Proceedings of the IEEE International Symposium on Biomedical Imaging (ISBI), 7-11 April, 2013, San Francisco, California, pp. 720-723. http://dx.doi:10.1109/ISBI.2013.6556576

Boguslaw Obara, Mark AJ Roberts, Judith P Armitage, Vicente Grau - Bacterial cell identification in differential interference contrast microscopy images - BMC bioinformatics 2013/4/23  14(1) Pages 134 - http://dx.doi:10.1186/1471-2105-14-134

MA Chappell, MW Woolrich, ET Petersen, X Golay, and SJ Payne.
Comparing model-based and model-free analysis methods for QUASAR arterial spin labeling perfusion quantification. 
Magnetic resonance in medicine, 69(5) May 2013: 1466-1475. http://dx.doi.org/10.1002/mrm.24372

ML Giger, N Karssemeijer, JA Schnabel.
Breast Image Analysis for Risk Assessment, Detection, Diagnosis, and Treatment of Cancer. 
Annual Review of Biomedical Engineering 15: July 2013: 327 - 357
 
MP Heinrich, M Jenkinson, Sir M Brady, JA Schnabel.
MRF-based deformable registration and ventilation estimation of lung CT.
IEEE Transactions on medical imaging 32 (7) July 2013: 1239-1248 http://dx.doi.org/10.1109/TMI.2013.2246577

HY Baluwala, L Risser, K Saddi, JA Schnabel.
Towards a physiologically motivated registration of diagnostic CT and PET/CT of lung volumes.
Medical Physics 40(2), 2013. http://dx.doi.org/10.1118/1.4771682


A Larrue, JA Noble.
Modelling of errors in Nakagami imaging: illustration of breast masses characterization.
Ultrasound in Medicine and Biology. In press. http://dx.doi.org/10.1016/j.ultrasmedbio.2013.11.018

D Augustine, AJ Lewandowski, M Lazdam, A Rai, J Francis, S Myerson,A Noble, H Becher,S Neubauer,SE Petersen, P Leeson.
Global and Regional Left Ventricular Myocardial Deformation Measures By Magnetic Resonance Feature Tracking In Healthy Volunteers: Comparison with Tagging and Relevance of Gender.
Journal of Cardiovascular Magnetic Resonance (BioMed Central); 15(1) 2013: 8 http://dx.doi.org/10.1186/1532-429X-15-8

TW Okell, MA Chappell, P Jezzard.
A theoretical framework for quantifying blood volume flow rate from dynamic angiographic data and application to vessel-encoded arterial spin labeling MRI. 
Medical Image Analysis, 17(8):1025–1036. 2013 http://dx.doi.org/10.1016/j.media.2013.06.005
 
S Rueda, S Fathima, CL Knight, M Yaqub, AT PapageorghiouB Rahmatullah, A Foi, M Maggioni, A Pepe, J Tohka,  RV Stebbing, JE McManigle, A Ciurte, X Bresson, M Bach Cuadra,C Sun, GV Ponomarev, MS Gelfand, MD Kazanov, C-W Wang,H-C Chen, C-W Peng, C-M Hung, and JA Noble.
Evaluation and Comparison of Current Fetal Ultrasound Image Segmentation Methods for Biometric Measurements: A Grand Challenge
IEEE Transactions on Medical Imaging 2013.  http://dx.doi.org/10.1109/TMI.2013.2276943

 

AL Namburete, B Rahmatullah, JA Noble.
Nakagami-Based AdaBoost Learning Framework for Detection of Anatomical Landmarks in 2D Fetal Neurosonograms.
doi
Annals of the British Machine Vision Association (BMVA), No. 2, 2013, p. 1-16.

 

MA Chappell, MJ Donahue, YK Tee, AA Khrapitchev, NR Sibson, P Jezzard, SJ Payne.
Quantitative Bayesian model-based analysis of amide proton transfer MRI.
Magnetic resonance in medicine, 70(2), Aug 2013: 556-567 http://dx.doi.org/10.1002/mrm.24474

 

A Cifor, L Risser, D Chung, EM Anderson, JA Schnabel. Hybrid feature-based diffeomorphic registration for tumour tracking in 2-D liver ultrasound images.
IEEE Transactions on Medical Imaging. 32(9) Sept 2013: 724-727 http://dx.doi.org/10.1109/TMI.2013.2262055

 

G Pons, J Marti, R Marti, S Ganau, J Carles Vilanova, JA Noble. Evaluating lesion segmentation in breast ultrasound images related to lesion typology.
doi
Journal of Ultrasound in Medicine 32: Sept 2013: 1659-1670
 
J Villar, D Altman, M Purwar, JA Noble, H Knight, P Ruyan, L Cheikh Ismail, F Barros, A Lambert, A Papageorghiou, M Carvalho, Y Jaffer, E Bertino, M Gravett, Z Bhutta, S Kennedy, and for the International Fetal and Newborn Growth Consortium for the 21st Century (INTERGROWTH-21st) (2013).
The objectives, design and implementation of the INTERGROWTH-21st Project. BJOG: An International Journal of Obstetrics & Gynaecology.
BJOG 120(s.2) Sept 2013: 9-26 http://dx.doi.org/10.1111/1471-0528.12047

 

A Cifor, L Risser, D Chung, EM Anderson, JA Schnabel. Hybrid feature-based diffeomorphic registration for tumour tracking in 2-D liver ultrasound images.
IEEE Transactions on Medical Imaging. 32(9) Sept 2013: 724-727 http://dx.doi.org/10.1109/TMI.2013.2262055
 

M Yaqub, C Ioannou, M K Javaid, C Cooper, A Papageorghiou, JA Noble.
Fusion of 3D ultrasound images of the fetal femur improves boundary definition and volume measurement.
Fetal Diagnosis and Therapy 34(3) Oct 2013:158-165 http://dx.doi.org/10.1159/000354342
 
P Brown, J Alsousou, A Cooper, M Thompson, JA Noble.
The AutoQual ultrasound elastography method for quantitative assessment of lateral strain in post rupture Achilles tendons.
Journal of Biomechanics- accepted.
Journal of Biomechanics, 46(15) 18 Oct 2013: 2695 - 2700 http://dx.doi.org/10.1016/j.jbiomech.2013.07.044
 
RV Stebbing, JA Noble. Delineating anatomical boundaries using the boundary fragment model. Medical Image Analysis.
Medical Image Analysis 17(8) Dec 2013:1123-1136 http://dx.doi.org/10.1016/j.media.2013.07.001
 
M Kuklisova-Murgasova, A Cifor, R Napolitano, A Papageorghiou, G Quaghebeur, MA Rutherford, JV. Hajnal, JA Noble, JA Schnabel.
Registration of 3D fetal neurosonography and MRI.
Medical Image Analysis.
Medical Image Analysis, 17(8) Dec 2013 :1137-1150 http://dx.doi.org/10.1016/j.media.2013.07.004

 

Conference Papers

 

MW Tee, SF Fathima, DA Bluemke, JA Noble.
Applications of Feature Based Attribute Vectors for Myocardium Tissue Characterization Towards Cardiac Motion Estimation in Cardiac Computed Tomography.
Proceedings of the Medical Image Understanding and Analysis (MIUA 2013).

JS Domingos, E Lima , P Leeson , JA Noble.
Local Phase-Based Fast Ray Features for Automatic Left Ventricle Apical View Detectionin 3D Echocardiograph.
MICCAI 2013: 4th International Workshop on Medical Computer Vision, Nagoya, Japan, Sept 22-26, 2013, LNCS, Springer (2013).
 
M Yaqub, R Cuingnet, R Napolitano, D Roundhill, A Papageorghiou, R Ardon, JA Noble.
Volumetric Segmentation of Key Fetal Brain Structures in 3D Ultrasound.
MICCAI 2013: 4th International Workshop on Machine Learning in Medical Imaging, Nagoya, Japan, Sept 22-26 2013.
 
A Cifor, L Risser, MP Heinrich, Daniel Chung, and Julia A. Schnabel.
Rigid Registration of Untracked Freehand 2D Ultrasound Sweeps to 3D CT of Liver Tumours
MICCAI 2013: 5th International Workshop on Abdominal Imaging: Computational and Clinical Applications, Nagoya, Japan, Sept 22-26 2013.
 
B Irving, LTanner, M Enescu, M Bhushan, EJ Hill, J Franklin, EM. Anderson, RA. Sharma, JA. Schnabel, M Brady.
Personalised Estimation of the Arterial Input Function for Improved Pharmacokinetic Modelling of Colorectal Cancer using dceMRI.
MICCAI 2013: 5th International Workshop on Abdominal Imaging: Computational and Clinical Applications, Nagoya, Japan, Sept 22-26 2013. In press.
 
MP Heinrich, I Simpson, M Jenkinson, M Brady, JA Schnabel.
Estimates for Improved Accuracy of Registration-Based Segmentation Propagation using Discrete Optimisation.
MICCAI 2013 Challenge Workshop on Segmentation: Algorithms, Theory and Applications Nagoya, Japan, Sept 22-26 2013 ("SATA").
 
Chykeyuk K, M Yaqub, JA Noble. 
Class-specific regression random forest for accurate extraction of standard planes from 3D echocardiography.
Proceedings for the Medical Image Computing and Computer Assisted Intervention (MICCAI), Nagoya, Japan, Sept 22-26, 2013, LNCS, Springer (2013).
 

M Bhushan, JA Schnabel, MA Chappell, FV Gleeson, EM Anderson, J Franklin, Sir M Brady, M Jenkinson.
The Impact of Heterogeneity and Uncertainty on Prediction of Response to Therapy Using Dynamic MRI Data.
Proceedings for the Medical Image Computing and Computer Assisted Intervention (MICCAI), Nagoya, Japan, Sept 22-26, 2013, LNCS, Springer (2013).

MP Heinrich, M Jenkinson, BW Papiez, M Brady, JA Schnabel.
Towards real-time multi-modal fusion for image-guided interventions using self-similarities.
Proceedings for the Medical Image Computing and Computer Assisted Intervention (MICCAI), Nagoya, Japan, Sept 22-26, 2013, LNCS, Springer (2013).

J. Jiao, JA Schnabel, RN Gunn.
A Generalised Spatio-Temporal Registration Framework for Dynamic PET Data: Application to Neuroreceptor Imaging.
Proceedings for the Medical Image Computing and Computer Assisted Intervention (MICCAI), Nagoya, Japan, Sept 22-26, 2013, LNCS, Springer (2013).

B Papiez, M Heinrich, L Risser, JA Schnabel.
Complex lung motion estimation via adaptive bilateral filtering of the deformation field.
Proceedings for the Medical Image Computing and Computer Assisted Intervention (MICCAI), Nagoya, Japan, Sept 22-26, 2013 2013, LNCS, Springer (2013).
Accepted for oral presentation.
Winner of a MICCAI 2013 Young Scientist Award.

IJ Simpson, MW Woolrich, MJ Cardoso, DM Cash, M Modat, JA Schnabel, S Ourselin.
A Bayesian Approach for Spatially Adaptive Regularisation in Non-Rigid Registration.
Proceedings for the Medical Image Computing and Computer Assisted Intervention (MICCAI), Nagoya, Japan, Sept 22-26 2013, LNCS, Springer (2013).
Winner of a MICCAI 2013 Young Scientist Award.

D Augustine, M Yaqub, C Szmigielski, E Lima,  S Neubauer, S Petersen, H Becher, JA Noble, P Leeson.

3D fusion echocardiography improves 3D left ventricular assessment: comparison with 2D contrast echocardiography.
Proceedings for the European Society of Cardiology Congress (ESC) 31 Aug 2013 - 04 Sep 2013, Amsterdam, Netherlands. 

C Arteta,  V Lempitsky, JA Noble, A Zisserman
Learning to Detect Partially Overlapping Instances.
Proceedings of the 26th IEEE Conference on Computer Vision and Pattern Recognition (CVPR 2013). June 25-27, 2013, Portland, USA.

MP Heinrich, M Jenkinson, B. Papiez, FV Gleeson, M Brady, JA Schnabel
Edge- and detail-preserving sparse image representations for deformable registration of chest MRI and CT volumes.
Proc Information Processing in Medical Imaging (IPMI 2013).

C Wessel, JA Schnabel, JM Brady.
Realistic biomechanical model of a cancerous breast for the registration of prone to supine deformations.
35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC'13).

S Rueda, C.L. Knight, AT Papageorghiou, JA Noble.
Oriented Feature-Based Coupled Ellipse Fitting for Soft Tissue Quantification in Ultrasound Images.
Proceedings of the IEEE International Symposium on Biomedical Imaging (ISBI) 2013: from Nano to Macro, April 2013, San Francisco, CA, USA.

R Cuingnet, O Somphone, B Mory, R Prevost, M Yaqub, R Napolitano, A Papageorghiou, D Roundhill, JA Noble, R Ardon.
Where is my Baby? A Fast Fetal Head Auto-Alignment in 3D-Ultrasound.
Proceedings of the the IEEE International Symposium on Biomedical Imaging (ISBI) 2013: from Nano to Macro, April 2013, San Francisco, CA, USA.

AIL Namburete,  JA Noble.
Fetal Cranial Segmentation in 2D Ultrasound Images Using Shape Properties of Pixel Clusters.
Proceedings of the IEEE International Symposium on Biomedical Imaging (ISBI) 2013: from Nano to Macro, April 2013, San Francisco, CA, USA.

Z Raeesy, S Rueda, JK Udupa.
Automatic Segmentation of Vocal Tract MR Images.
Proceedings of the IEEE International Symposium on Biomedical Imaging (ISBI) 2013: from Nano to Macro, April 2013, San Francisco, CA, USA.

M Enescu, M Bhushan, EJ Hill, J Franklin, EM Anderson, RA Sharma,  JA Schnabel.
pCT derived arterial input function for improved pharmacokinetic analysis of longitudinal dceMRI for colorectal cancer  
Proceedings of SPIE Medical Imaging 2013 - Image Processing, Orlando, Florida, USA, 9-14 February 2013.

TM Rackham, S Rueda, CL Knight, JA Noble.
Ultrasound image segmentation using feature asymmetry and shape guided live wire.
Proceedings of SPIE Medical Imaging 2013: Image Processing, Orlando, Florida, USA, 9-14 February 2013.

JS Domingos, D Augustine, P Leeson, JA Noble.
Automatic Left Ventricle Apical Plane Detection In 3D Echocardiography.
Proceedings of SPIE Medical Imaging 2013: Image Processing, Orlando, Florida, USA, 9-14 February 2013.

 

Conference Abstracts


EJ Hill, J Franklin, M Enescu, T Pwint, JA Schnabel, EM Anderson, G Brown, WG McKenna, T Maughan, and R Sharma. Phase 0-I clinical trial of nelfinavir with hypofractionated radiotherapy for rectal cancer: Clinical safety and changes in tumour perfusion observed. 8th NCRI conference, 2013.

S Rueda, CL Knight, AT Papageorghiou, JA Noble.
Systematic thickness analysis of the adipose tissue around the fetal arm across gestation using 2D ultrasound images.
Proceedings of the 23rd World Congress on Ultrasound in Obstetrics and Gynecology - ISUOG 2013, 6-9 October 2013, Sydney, Australia.
 
S Rueda, CL Knight, AT Papageorghiou, JA Noble.
Novel automatic coupled ellipse fitting tool for fetal arm adipose tissue quantification in 2D ultrasound images across gestation.
Proceedings of the 23rd World Congress on Ultrasound in Obstetrics and Gynecology - ISUOG 2013, 6-9 October 2013, Sydney, Australia.
 
CL Knight, S Rueda, JA Noble, AT Papageorghiou.
Fetal fat index: a novel technique to assess fetal arm fat.
Proceedings of the 23rd World Congress on Ultrasound in Obstetrics and Gynecology - ISUOG 2013, 6-9 October 2013, Sydney, Australia.
 
CL Knight, S Rueda, M Ahmed, K Edwards, JA Noble, AT Papageorghiou.
Fetal arm volumetry: a novel assessment of fetal body composition in the second and third trimester.
Proceedings of the 23rd World Congress on Ultrasound in Obstetrics and Gynecology - ISUOG 2013, 6-9 October 2013, Sydney, Australia.
 
M Ahmed, CL Knight, S Rueda, AT Papageorghiou, JA Noble.
Assessing fetal fractional arm volume using varying numbers of cross-sectional slices.
Proceedings of the 23rd World Congress on Ultrasound in Obstetrics and Gynecology - ISUOG 2013, 6-9 October 2013, Sydney, Australia.
 

J Jiao, GE Searle, JA Schnabel, RN Gunn.
Impact of subject motion correction on dopamine D3 receptor imaging with [11C]PHNO PET and a selective D3 receptor antagonist.
XXVIth International Symposium on Cerebral Blood Flow, Metabolism and Function & XIth International Conference on Quantification of Brain Function with PET. Shanghai, China, May 20th – 23rd, 2013.

A Kopuri, S Rueda, C Knight, K McCormick, JA Noble, A Papageorghiou, P Sullivan.
Neonatal peripheral adiposity measurements using 2D ultrasound in premature infants and comparison with fetal adiposity measures - a novel marker for nutritional status.
48th annual meeting of ESPGHAN, 8-11 May 2013, London UK. 

J. Alsousou, P. G. Brown, M. Thompson, K. Willett, A. J. Noble
Ultrasound Elastography Imaging of Healing Ruptured Achilles Tendons: a Measure of Mechanical Healing
EFORT 2013. Abstract

JA Schnabel.
Respiratory motion correction in lung imaging.
EFOMP Workshop on New technology in diagnostic radiology: new frontiers in imaging of the lung. European Congress of Radiology 2013.

J Franklin, M Enescu, EJ Hill, RA Sharma, JA Schnabel, FV Gleeson, EM Anderson.
A perfusion CT-derived patient-specific arterial input function for pharmacokinetic modeling of dynamic contrast enhanced MRI.
European Congress of Radiology 2013.

M Bhushan, M Enescu, C Galerneau, M Anderson, F Gleeson, M Brady, JA Schnabel, M Jenkinson.
Quantifying response to CRT in colorectal cancer patients from dynamic imaging.
Novel technology that shapes Radiology: EIBIR presents IMAGINE, European Congress of Radiology 2013.

M Heinrich, B Papiez, L Risser, T Matin, M Brady, M Jenkinson, F Gleeson, JA Schnabel.
Respiratory motion estimation of multi-modal CT/MRI lung volumes.
Novel technology that shapes Radiology: EIBIR presents IMAGINE, ECR 2013.

NS Hartkamp, M Helle,, MA Chappell, TW Okell, RPH Bokkers, J Hendrikse, MJP Van Osch.
The Use of k-Means Clustering and Bayesian Inference Framework for the Processing of Vessel-Encoded P-CASL Images as Compared with Super-Selective P-CASL MRI. 
Proceedings for the International Society of Magnetic Resonance in Medicine 21st Annual Meeting. Salt Lake City, USA, 20-26 April 2013; 0102
 
TW Okell, UG Schulz, MA Chappell, M Garcia, W Küker, P Jezzard.
Comparison of Vessel-Encoded Arterial Spin Labeling Dynamic Angiography with X-Ray Digital Subtraction Angiography in Patients with Vertebrobasilar Disease.
Proceedings for the International Society of Magnetic Resonance in Medicine 21st Annual Meeting. Salt Lake City, USA, 20-26 April 2013; 0623.
 
TW Okell, M Garcia, MA Chappell, JV Byrne, P Jezzard.
Assessment of Arterial Supply to Arteriovenous Malformations with Vessel-Encoded Arterial Spin Labeling Dynamic Angiography
Proceedings for the International Society of Magnetic Resonance in Medicine 21st Annual Meeting. Salt Lake City, USA, 20-26 April 2013; 1128.
 
M Garcia, M, TW Okell, M Gloor, MA Chappell, P Jezzard, O Bieri, JV Byrne.
Utility of Flat Panel Detector CT (FPD-CT) in Perfusion Assessment of Brain Arteriovenous Malformations.
Proceedings for the International Society of Magnetic Resonance in Medicine 21st Annual Meeting. Salt Lake City, USA, 20-26 April 2013; 1137.
 
M Castellaro, A Mehndiratta, D Peruzzo, G Pillonetto, ET Petersen, X Golay, X, MA Chappell, A Bertoldo.
Cerebral Blood Flow Quantification from QUASAR ASL by Stable Spline.
Proceedings for the International Society of Magnetic Resonance in Medicine 21st Annual Meeting. Salt Lake City, USA, 20-26 April 2013; 2172.
 
EAH Warnert, AD Harris, K Murphy, MA Chappell, JE Hall, RG Wise.
Measuring Tissue Perfusion in the Human Brainstem Using Multi-Inversion Time Pulsed Arterial Spin Labelling.
Proceedings for the International Society of Magnetic Resonance in Medicine 21st Annual Meeting. Salt Lake City, USA, 20-26 April 2013; 2182.
 
M Garcia, M Gloor, MA Chappell, P Jezzard, JV Byrne, O Bieri, TW Okell.
The Value of Vessel-Encoded Pseudocontinuous Arterial Spin Labelling (VEPCASL) in Perfusion Assessment of Brain Arteriovenous Malformations: Comparison with Dynamic Susceptibility Contrast (DSC)-MRI.
Proceedings for the International Society of Magnetic Resonance in Medicine 21st Annual Meeting. Salt Lake City, USA, 20-26 April 2013; 2989.
 
S Rane, P Donahue, TF Towse, S Ridner, JC Gore, MA Chappell, MJ Donahue.
Measurement of Reduced Lymphatic Flow Velocity Under Conditions of Obstructed Lymphatic Flow Using Spin Labeling Approach.
Proceedings for the International Society of Magnetic Resonance in Medicine 21st Annual Meeting. Salt Lake City, USA, 20-26 April 2013; 3048.

A Mehndiratta, BJ  MacIntosh, DE Crane, SJ Payne, MA Chappell.
Quantifying Cerebral Haemodynamics Beyond CBF Using Control Point Interpolation Deconvolution for DSC MRI Perfusion Analysis. 
Proceedings for the International Society of Magnetic Resonance in Medicine 21st Annual Meeting. Salt Lake City, USA, 20-26 April 2013; 3068.
 
A Mehndiratta, F Calamante, BJ MacIntosh, DE Crane, SJ Payne, MA Chappell.
DSC-MRI Simulations: What Is the Correct Model for the in vivo Tissue Residue Function?
Proceedings for the International Society of Magnetic Resonance in Medicine 21st Annual Meeting. Salt Lake City, USA, 20-26 April 2013; 3069.
 
A Mehndiratta, F Calamante, BJ MacIntosh, DE Crane, SJ Payne, MA Chappell.
CBF Quantification in the Face of Dispersion and Separation of Its Effects from Normal Cerebral Haemodynamics: A Comparison of Deconvolution Methods in DSC-MRI.

Proceedings for the International Society of Magnetic Resonance in Medicine 21st Annual Meeting. Salt Lake City, USA, 20-26 April 2013; 3070.

R Oliver, MA Chappell, D Thomas, X Golay.
Comparison of Bayesian and Linear Regression-Based Partial Volume Correction in Single Time Point ASL.
Proceedings for the International Society of Magnetic Resonance in Medicine 21st Annual Meeting. Salt Lake City, USA, 20-26 April 2013; 3727.
 
R Ouwerkerk, YK Tee, CK Jones.
Glycogen Chemical Exchange Effects in 1H-MRS and Glyco-CEST at 3T and 7T 
Proceedings for the International Society of Magnetic Resonance in Medicine 21st Annual Meeting. Salt Lake City, USA, 20-26 April 2013; 3990.
 
YK Tee, MJ Donahue, SJ Payne, MA Chappell.
Does It Affect the Quantification If Amide Proton Transfer Imaging Is Performed Pre- Or Post-Gadolinium Contrast Agent Administration?
Proceedings for the International Society of Magnetic Resonance in Medicine 21st Annual Meeting. Salt Lake City, USA, 20-26 April 2013; 4234.